About Uninyvin Cables
- Uninyvin Cables, has superior properties, ifcompared with PVC cables, it has1. Low weight ratio, for a given current, nearly 1/3is cross section used for similar current capacity.
- High temperature range, from Minus 30 deg 0C to 105 deg 0Ccompared to conventional PVC cable, and from20 deg C to 70 deg C
- Cost effective, due to less size
- Abrasion Resistance - Good
- Mechanical Strength - High
- Resistance to Oils, Fluids, Alkalies, and Fungus growth
- High Fire Retardancy
- The conductor is tin plated so, solderability isgood and oxidation of conductor is protected.
|
Part number
|
Uninyvin cable
|
Size (mm)
|
Conductor Diameter max
|
Cable dia mm
|
Conductor resistance
|
Max current rating
|
|
RJ part no.
|
Type
|
Sq. mm
|
mm
|
max
|
min
|
ohm/900 meter max at 20 deg C
|
Single core in free air
|
|
1701 00 22
|
22
|
0.347
|
0.838
|
2.0
|
1.8
|
49.66
|
11
|
|
1701 00 20
|
20
|
0.566
|
1.04
|
2.3
|
2.0
|
30.95
|
14
|
|
1701 00 18
|
18
|
0.966
|
1.32
|
2.5
|
2.3
|
17.82
|
18
|
|
1701 00 16
|
16
|
1.170
|
1.55
|
2.8
|
2.5
|
14.70
|
21
|
|
1701 00 14
|
14
|
2.050
|
1.95
|
3.4
|
3.0
|
8.41
|
31
|
|
1701 00 12
|
12
|
3.220
|
2.43
|
3.8
|
3.5
|
5.35
|
43
|
|
1701 00 10
|
10
|
5.330
|
3.15
|
5.0
|
4.6
|
3.23
|
61
|
|
1701 00 08
|
8
|
8.760
|
4.24
|
6.3
|
5.9
|
1.97
|
87
|
|
1701 00 06
|
6
|
13.300
|
5.54
|
7.5
|
7.3
|
1.30
|
115
|
|
1701 00 04
|
4
|
21.500
|
6.90
|
9.3
|
8.8
|
0.802
|
160
|
|
1701 00 02
|
2
|
33.300
|
8.76
|
11.0
|
10.5
|
0.515
|
200
|
|
1701 00 01
|
1
|
40.700
|
9.75
|
12.2
|
11.7
|
0.423
|
220
|
|
1701 11 10
|
0
|
53.00
|
11.0
|
13.7
|
13.0
|
0.325
|
240
|
|
1701 11 00
|
00
|
68.300
|
12.4
|
15.4
|
14.6
|
0.252
|
270
|
|
1701 10 00
|
000
|
84.200
|
13.9
|
16.9
|
16.1
|
0.204
|
300
|
|
1701 00 00
|
0000
|
109.000
|
15.6
|
18.7
|
17.9
|
0.158
|
350
|
Reliable Quality and Safety ComplianceUninyvin Cables meet rigorous standards including IS 694, RoHS, and flammability criteria (IS 10810-53), ensuring long-term safety and compliance in industrial and aviation environments. The cables exhibit low smoke emission, high dielectric strength, and flame-retardant characteristics, providing peace of mind in hazardous situations where fire resistance is vital.
Versatile Applications and CustomizationDesigned for both fixed and flexible laying, Uninyvin Cables can be tailored in terms of length, core number, and dimensions to suit diverse requirements. Their excellent oil, acid, and alkali resistance, along with temperature tolerance ranging from -20C to +105C, make them apt for aircraft wiring, control panels, and demanding industrial setups.
FAQs of Uninyvin Cables:
Q: How do Uninyvin Cables ensure safety in hazardous environments?
A: Uninyvin Cables are designed with high dielectric strength (3.5 kV for 1 minute), flame-retardant PVC insulation, and low smoke emission, minimizing risk during electrical faults and ensuring compliance with IS 694 and IS 10810-53 flammability standards.
Q: What applications are suitable for Uninyvin Cables?
A: These cables are ideal for aircraft wiring, industrial control panels, and instrumentation. Their flexibility and robust insulation make them suitable for both fixed and movable installations in demanding workspaces.
Q: When should you choose Uninyvin Cables over standard wires?
A: Opt for Uninyvin Cables when you require cables that can withstand higher temperatures (up to 105C), exposure to oil, acids, and alkalis, or need enhanced fire safety and low-smoke characteristics within equipment or confined areas.
Q: Where can you get Uninyvin Cables packaged according to your needs?
A: Uninyvin Cables are available in coils or drums, with optional meter marking on request, and can be supplied through distributors, exporters, and manufacturers across India; online and direct purchase options are provided by leading suppliers.
Q: What process is followed in manufacturing Uninyvin Cables?
A: The cables are produced using annealed tinned copper conductors with special grade PVC insulation and jacket. Manufacturing adheres strictly to IS 694, ensuring each piece is flame retardant, RoHS compliant, and meets exceptional mechanical and electrical standards.
Q: How does the cables bending radius affect installation?
A: With a recommended minimum bending radius of 6 times the overall diameter, Uninyvin Cables are easy to install in both tight and spacious configurations without compromising cable integrity or performance.
Q: What benefits do Uninyvin Cables provide for users?
A: They offer reliable performance in critical applications, longevity due to high tensile strength, greater safety from fire and chemicals, customization for project needs, and excellent compliance with global and national standards.